Karl Fischer reagents are used to determine the moisture content of a sample. It’s a fast and easy method that requires only a small amount of sample.
Moisture Measurement - Karl Fischer Titrimetry 2nd Edition
We stock Karl Fischer reagents primarily from GFS chemicals and MilliporeSigma. Our almost 100-years of experience tell us these are preferred by labs like yours because:
They’re the best value on the market
They have excellent product availability
They’re well regarded for consistent product quality
They’re backed by industry leading manufacturing processes
That’s all well and good. But…
...continue reading below the images
2978 SOLVENT FOR OILS, ONE-COMPONENT WATERMAR More...
SILICA GEL, w/30% INDICATING BEADS, 3-10 MESH
5 mg/mL, 2-COMPONENT KARL FISCHER TITRANT. ST More...
1619 ANOLYTE VESSEL SOLUTION, FOR KETONES AND More...
5 mg/mL KARL FISCHER TITRANT. WATERMARK 1600. More...
1609 METHANOL-FREE, WATERMARK KARL FISCHER SO More...
3569 METHYL ALCOHOL, ANHYDROUS, WATERMARK KAR More...
1609 METHANOL-FREE, WATERMARK KARL FISCHER SO More...
CombiCoulomat Fritless Volumetric Solvent, 50 More...
5 mg/mL KARL FISCHER TITRANT. WATERMARK 1600. More...
2978 SOLVENT FOR OILS, ONE-COMPONENT, WATERMA More...
XYLENE, ACS REAGENT. 500 mL
Our job is to make your job easy.
We have near-century-long relationships with many of your preferred manufacturers. Which means you get realistic and honest ETAs on product availability.
Many of your essential Karl Fischer reagents are already in stock in our warehouse in Pennsylvania.
But if the reagents you need aren't in stock, and if the supply chain doesn't work with your timeline, we can get you good alternatives that fit your need. So you don't have to waste time searching.
It saves you the legwork and keeps your lab productive when others are waiting for orders that are still 6-months away.
Tell us what you need. We'll tell you when you can actually get it, and give you the alternatives that can get to you sooner.
Q: What is drift in Karl Fischer titration?
A: Drift is the moisture detected inside the vessel that doesn't come from your sample. Drift (background moisture) can occur when the vessel has been unused for a while and moisture has infiltrated and accumulated inside, or it may be the result of a leak that allows a small amount of moisture to enter the vessel regularly.
Q: What's the best Karl Fischer electrode?
A: The answer is subjective. But you can find electrodes and more here.
Q: What's the difference between coulometric and volumetric?
A: Volumetric titration is typically selected for samples in the 100 parts per million to 100% water content range, although sample analysis down 10 ppm water is possible. Coulometric titration is typically selected with a water content of less than 1%, although samples with water content up to 5% are possible.
Q: What's the difference between one component and two component Karl Fischer reagents?
A: One component Karl Fischer reagents are most commonly used. They are the least expensive. If your lab is on a budget, or performs frequent KF titrations, these are likely your preferred choice. If you need a greater accuracy, speedier titrations, or less frequent standardization, choose a two component system.
GFS Karl Fischer Standards and Reagents | GFS Karl Fischer Drying Agents | GFS Karl Fischer water standards |
Reagents List for ASTM D664 | Reagents List for ASTM D2896 |