Measurement Module, 12 L x 6 W x 9.5 cm H, pH with LogR Temperature/mV/(RmV)/ORP with Temperature Measuring Modes, -5 to 105°C/22 to 221°F Temperature Range, -2 to 20 pH Range, ±2000 mV Range, ±2000 Relative mV Range
Add pH, mV, ORP and LogR temperature measurement capabilities to your Thermo Scientific™ Orion™ Versa Star™ meter using the Thermo Scientific™ Orion™ Versa Star™ pH/LogR Measurement Module. Each Orion™ Versa Star™ meter has four channels that can be customized with interchangeable measurement modules. The Orion™ Versa Star™ pH/LogR module offers LogR temperature technology that uses the glass-bulb of most pH electrodes to measure both pH and temperature at the same location - ideal for small sample volumes and samples that are difficult to clean. Select from five Thermo Scientific™ Orion™ Versa Star™ measurement modules to customize the measurement capabilities of your Orion™ Versa Star™ meter. Measurement modules are interchangeable and can be added or removed from each Versa Star™ meter's four channels at any time.
Alarm Output | : | Set Point Alarm, High/Low Limit Alarm, Calibration Due Alarm |
Calibration | : | pH with Calibration Editing Option, Relative mV (RmV), ORP, LogR Temperature and Temperature |
Connector Type | : | Input: BNC (pH or ORP Electrode), Pin-tip (Reference Electrode), 8-pin MiniDIN (ATC Temperature Probe) |
Includes | : | Versa Star pH/LogR Module and Printed Quick Start Guide |
Isopotential Point | : | 7 pH (Adjustable) |
Measuring Modes | : | pH with LogR Temperature/mV/Relative mV (RmV)/ORP with Temperature |
Method | : | 10 per Channel with Password Protection |
mV Range | : | ±2000 mV |
mV Resolution | : | 0.1 mV |
Operating Temperature | : | 5 to 45°C (ambient) |
ORP Range | : | ±2000 mV |
pH Accuracy | : | ±0.002 |
pH Calibration Point | : | 1 to 6 |
pH Range | : | -2 to 20 |
pH Resolution | : | 0.1, 0.01, 0.001 |
Probe Type | : | pH Electrode, ORP Electrode, Reference Half-cell Electrode, ATC Temperature Probe |
Dimension | : | 12 L x 6 W x 9.5 cm H |
Stability | : | Selectable Fast, Medium, Slow or Smart Stability Setting, Selectable off or Automatic Smart Averaging Setting |
Temperature Resolution | : | 0.1°C, 0.1°F |
Temperature Selection | : | Manual or Automatic with ATC Temperature Probe, Automatic with pH Electrode Using LogR Mode |
mV Accuracy | : | ±0.2 mV or ±0.05% of reading whichever is greater |
Relative Humidity Range | : | 5 to 85%, Non-condensing |
Relative mV Range | : | ±2000 mV |
Temperature Accuracy | : | ±0.1°C |
Temperature Probe Calibration | : | 1 Point Temperature Offset |
Temperature Range | : | -5 to 105°C, 22 to 221°F |